Direct answer:TR CU 012/2011 covers electrical/non-electrical equipment and Ex components intended for explosive atmospheres. Key identification factors include explosion-protection measures and markings in manufacturer documents. Mandatory certification applies; verify scope, category and markings against hazardous areas, equipment groups and annexes.

Scope and Exclusions

Safety of Equipment for Use in Explosive Atmospheres covers defined equipment and Ex components, rather than every product that might contact flammables. Exclusions include medical devices, certain non-industrial equipment, PPE, transport and other categories. Check each clause; explosion risks onsite or industrial use alone cannot establish applicability.

Assessment and Markings

Certification is performed by a body in the Union unified register. Correctly determine equipment group, category/level, atmosphere type and protection method, which govern permissible hazardous areas. Separately assess other applicable regulations, including low voltage, EMC and machinery safety.

Project Preparation Sequence

  1. Describe intended use, proposed hazardous installation area, medium and environmental parameters.
  2. Identify standalone equipment versus Ex components and compile manufacturer's explosion-protection design and marking information.
  3. Check TR CU 012/2011 definitions, annexes and exclusions to determine certification objects and schemes.
  4. Prepare designs, risk/explosion-protection analyses, instructions, drawings, component information and test evidence.
  5. Have qualified bodies arrange review and testing; after certification, check explosion-protection markings and document scope.

Explosion-protection applicability involves hazardous-area classification and equipment characteristics. This article does not replace site risk assessment or establish suitability for every hazardous area.

Official Basis

Sources reviewed: 13 November 2026.

Explore Machinery Service ScopeDiscuss Your Product