Direct answer:TR CU 020/2011 governs EMC for covered technical equipment: emissions must not prevent other equipment operating as intended, and immunity must suit the intended electromagnetic environment. Not all powered products automatically qualify. Check scope, exclusions and unified lists. Assess TR CU 004/2011 low-voltage applicability separately.

First Determine Whether It Is Defined Technical Equipment

TR CU 020/2011 was adopted by Customs Union Commission Decision No. 879 of 9 December 2011. Check technical-equipment definitions, independent use and scope. Components not intended for independent use, electromagnetically passive equipment and other express exclusions may fall outside the regulation; verify the complete provisions.

EEC explanations on measuring instruments refer to specific product groups in the unified list. Electronic components or marketing classifications alone cannot determine applicability; check current regulations, lists and technical characteristics.

Keep TR CU 020/2011 and TR CU 004/2011 Distinct

TR CU 020/2011 addresses EMC; TR CU 004/2011 addresses low-voltage safety. Products may fall under both, only one, or additional machinery, radio or metrology systems. Check each regulation's scope, exclusions, evidence and assessment independently.

Product Documents and Assessment Sequence

  1. Describe functions, independent use, power and interfaces, operating modes, installation environment and all models.
  2. Check TR CU 020/2011 scope/exclusions and relevant groups in the current Union unified product list.
  3. Assess TR CU 004/2011 and other specific regulations independently.
  4. Use product categories and annexes to determine certification or declaration, scheme and eligible applicant.
  5. Prepare technical descriptions, instructions, construction/model information, risks, test evidence and manufacturer/applicant documents. Confirm specifics by product and scheme.
  6. Complete prescribed testing and assessment; verify document records and markings.

Common Misunderstandings and Limitations

  • A circuit board or power supply does not necessarily establish TR CU 020/2011 applicability.
  • Exclusion from TR CU 020/2011 does not establish exemption from TR CU 004/2011 or other rules.
  • Standards and reports form part of the evidence; they do not automatically confer EAEU assessment documents.

This article supports regulatory screening preparation rather than replacing formal assessment against product facts, current unified lists and effective regulations.

Official Basis

Official sources reviewed: 13 November 2026.

Explore Electrical Product Service ScopeDiscuss Your Product